Features
1.12.1 inch high brightness color LCD/touch screen;
2.Various operation modes of buttons, knobs and touch screens;
3.Support multi-channel 8 waveform with screen display;
4.It has the analysis of arrhythmia, which supports three modes of monitoring, monitoring and operation.Blood oxygen saturation detection accuracy high, support weak pulse detection function;
5.The non-invasive blood pressure measurement supports manual, automatic and continuous mode, which can meet the needs of monitoring in various situations and greatly reduce the work intensity of medical staff.It has 400 sets of blood pressure lists, 6,000sec waveform review, 60 alarm record reviews, 7 days trend chart storage
function;
6.Voice, text and visual alarm function, level 3 alarm, provide physiological alarm and technical alarm, the lower limit of physiologi- cal alarm can be set according to
need;
7.Support multiple interface display: standard interface, trend coexistence interface, oxyCRG interface, large font interface;
8.Supports multiple languages: Chinese, English, Spanish, polish, Turkish, French, Portuguese, Russian;
9.Built-in high capacity battery, long battery life, easy to transfer animals;
10.Optional print output function, support alarm trigger print; Anti - defifibrillation, anti - frequency electric knife interference. Support for wired or wireless central
monitoring systems;
11.Optional extension function module (dual channel IBP, ETCO2), plug and play, software automatic recognition, interface dynamic adjustment,The module can be
hot-plug;
12.It can be used in cats, dogs, pigs, horses and other small, medium and large animals. Animal special accessories for different types of animals;
ECG specification
1. Lead mode: five lead or three lead Is optional
2. Accuracy. = 19 or t 1bpm, take big
3. Resolution: 1 BPM (stroke / min)
Breathing specification
1. Methods of measurement: RA-LL impedance method
2. Range of measurement: large animal: 0 to 120BrPM medium/small animal: 0-150 BrPM
In the range from 7B.PM to 120BrPM, the measurement error should be = 2BrPM.
Other range errors are not defined
Blood oxygen specification
1. Measuring range: 0 ~ 100%
2. Resolution: 196
3. Accuracy: within the range of 7096 to 10046, the measurement error shalt be = 4%;
The measurement error is not defined in the range of 0% to 6996
Pulse rate specification
1. Measuring range: 30 - 240bpm
2. Resolution: 16pm
3. Accuracy: = 3bpm
Nonirwasive blood pressure standard
1. Measurement technique: oscillation method
2. Measurement parameters: systolic / dilastolle/average pressure
3, Measurement mode: manual, continuous; automatic
4. Continuous measurement mode measurement time; 5 minutes
Body temperature specilication
1. Channels: dual channel
2. Measuring range: 0-50 °C
3. Resolution: 0.1 c
4. Accuracy: ‡0.1*C(excluding sensor error)
ETCO2
1. Measurement: infrared radiation absorption technology
2. Measuring range: 0 - 99mmHg
3. Accuracy 0 to 40mmHg: † 2% 41 to 76mmHg: #5% 77 to 99mmHg: ‡10%
4, Resolution: 1mmHg
Invasive blood pressure standard
1. Channels: dual channel
2. Pressure names: APT, PA, CVP, RAP, LAP, ICP, P1, P2
3. Range of measurement and alarm ranged from ART:0 to 300mmHg
PA:-6 to 120mmHg
CVP/RAP/LAP/CP.-10 to 40mmHg P1/P2:-10 to 300mmHg
4. Pressure sensor
Sensitivity: 5uw/V/mmH impedance range: 300-3000, resolution: ImmHg
Accuracy: + 2% or + 1mmHg, take big update time: about 1 minutes